When I buy or evaluate a used FANUC relay output module, I do not accept “tested good” as sufficient proof. What Test Evidence Should You Request for a Used AOR16G Module? At minimum, request identity and compatibility evidence, channel-by-channel electrical test results, relay contact measurements, inspection photographs, repair history, and written warranty or return terms. These records help distinguish a powered-up module from one that has passed a meaningful functional test.
The AOR16G is a 16-point relay output module used in FANUC I/O systems. Common references include A03B-0819-C161, while related FANUC Module I/O references such as A03B-0807-C161 may belong to a different I/O arrangement or product generation. I would never approve a replacement based only on the “AOR16G” name because the full part number, revision, connector arrangement, and rack compatibility determine whether the module can be installed safely.
!
For a purchasing decision, I request five evidence categories:
A supplier that cannot provide these five categories may still have a usable part, but the evidence package is incomplete. I would price that unit as an unverified used module rather than as a tested or refurbished replacement.
The FANUC AOR16G is a digital relay output module with 16 individually controlled output points. Each output uses a relay contact to switch an external circuit, allowing the FANUC control system to operate devices such as contactors, solenoid valves, indicator circuits, and auxiliary relays. The module does not normally power the controlled load by itself; the external circuit supplies the voltage that passes through the relay contact.
The commonly listed electrical limits are 30 VDC or 250 VAC, with a maximum rating of 2 A per point for a resistance load. These figures are not permission to connect every channel to a 2 A load simultaneously, because common-current, wiring, duty-cycle, inrush-current, and load-type restrictions may also apply. I compare the proposed application with the applicable FANUC manual rather than relying only on a reseller’s product description.
The output command typically comes from the FANUC controller through the I/O rack and base-unit arrangement. The module then energizes or releases the relevant relay, changing the state of the associated contact. For that reason, a bench test must verify both the control-side response and the load-side contact behavior.
An AOR16G module test report should identify the exact unit that was tested and explain how the results were obtained. I expect the report to show the test date, technician or test station, module part number, serial number, revision, supply voltage, test fixture, load type, measured values, and pass/fail result for each output. A document containing only “power on: yes” does not establish relay performance.
The report should also state whether the unit was tested as used, repaired, refurbished, or simply inspected. These terms describe different levels of work, and the purchasing risk changes accordingly. A supplier should not describe visual inspection as functional testing or describe a power-up check as a 16-channel load test.
| Report Item | Evidence I Would Request | Why It Matters |
|---|---|---|
| Identification | Part number, model, revision, serial number, nameplate photo | Prevents variant and serial-number errors |
| Electrical setup | Supply voltage, load voltage, current, wiring diagram | Shows whether the test represented the intended application |
| Channel results | Outputs 1–16 listed individually | Identifies weak, intermittent, or failed points |
| Relay measurements | Contact resistance and open-state isolation | Detects burned, welded, or contaminated contacts |
| Functional behavior | Energize, release, switching, and response observations | Confirms actual relay operation |
| Inspection record | Housing, terminals, connectors, corrosion, repairs | Reveals mechanical and maintenance risks |
| Protection terms | Warranty period, return rules, exclusions | Defines the buyer’s recovery option |
If the supplier is YaoTai technology, I would send this information as a written purchase requirement before payment. That gives both sides a fixed definition of “tested” and makes it easier to compare one offer with another.
The first inspection is identity verification. I request close, readable photographs of the front label, side label, terminal markings, connector area, and any barcode or serial-number plate. The supplier should provide the exact A03B-0819-C161 reference when that is the unit being offered, not only “FANUC AOR16G.”
I also check whether the listing refers to Fanuc Module I/O A03B-0807-C161. Similar-looking A03B numbers can represent different I/O units, revisions, terminal configurations, or system applications. If the supplier cannot explain the relationship between A03B-0807-C161 and A03B-0819-C161, I treat the offer as a compatibility risk.
The serial number should match the photographs, test report, packing label, and invoice. If a supplier sends a generic stock image, I request current photographs of the actual unit before accepting the test report. A report for one serial number cannot be used as evidence for another unit unless the supplier clearly documents the transfer and retest.
Before purchasing, I provide the supplier with the intended FANUC controller or I/O system, rack type, base unit, existing module position, cable arrangement, output voltage, load current, and terminal wiring. The supplier should confirm whether the proposed AOR16G variant fits that arrangement. Compatibility should be confirmed in writing rather than inferred from physical dimensions.
I also compare the terminal numbering and output grouping with the existing installation. A module may have the same output count but different connector or common-terminal requirements. If the replacement changes the common arrangement, an apparently successful bench test may not protect the machine installation.
AOR16G relay output testing should cover all 16 channels, not only one sample point. For each output, I want to see the relay in its inactive state, the relay commanded active, and the contact returned to the inactive state. The record should identify the measured voltage, current, load type, switching cycles, and final result.
A continuity test is useful but limited. It can confirm that a circuit is open or closed under a particular condition, yet it may not reveal contact resistance that rises under load or a relay that becomes intermittent after heating. I therefore request both low-current continuity measurements and functional switching under an appropriate load.
The test fixture should match the intended electrical category. A low-voltage lamp or meter may prove that a relay changes state, but it does not reproduce the stress of a contactor coil, solenoid, or other inductive load. The report should state whether the load was resistive, inductive, or simulated, and whether suppression components were used where required.
For each relay channel, I request:
The contact-resistance result should include the measurement method and test current because readings can vary with the instrument and surface condition. I do not treat an unexplained resistance number as conclusive. The supplier should compare the result with the applicable FANUC specification or internal acceptance limit.
A relay that works once may still fail in service. Welded contacts can leave an output permanently active, while contaminated or worn contacts may work at low current and fail at higher current. These conditions are why I place greater weight on channel-by-channel load testing than on a single photograph showing a powered module.
The published operating limits commonly associated with the AOR16G include 30 VDC, 250 VAC, and 2 A per point for resistance loads. I use these values as boundaries, not as a complete application design guide. The test report should also address common-current restrictions, grouping, duty cycle, inrush current, and the expected relay switching frequency.
For example, a module that passes a 24 VDC control-lamp test has not necessarily demonstrated safe operation with a 250 VAC load. Likewise, a relay that passes a static continuity test has not necessarily demonstrated acceptable behavior with an inductive solenoid. I ask the supplier to state exactly how the test conditions compare with the intended machine circuit.
Response behavior should also be recorded when the application depends on timing. The supplier does not need to invent a response-time value; instead, the report should identify the measured energizing and release behavior and compare it with the applicable FANUC manual specification. If no timing measurement was taken, the report should say so clearly.
The physical inspection should include the terminal block, mounting points, housing, circuit board area if accessible, connectors, labels, seals, and protective covers. I look for cracked plastic, missing terminal barriers, bent pins, oxidized contacts, discoloration from heat, contamination, and evidence that the module was exposed to oil or coolant. Any missing cover or damaged terminal should be recorded before shipment.
I also ask whether the unit has been repaired. A repaired module may be suitable for service, but I need the repair scope, replaced components, workmanship inspection, and post-repair test results. If relays, fuses, terminal blocks, or connectors were replaced, the supplier should identify the parts and explain whether all 16 channels were retested afterward.
A refurbished AOR16G should have more documentation than a used unit. Refurbishment normally implies a defined inspection or repair process, while “used and tested” may mean only that the unit powered up and produced an output. I do not assume that either label guarantees a particular process unless the supplier describes it in writing.
Yes, a supplier can perform meaningful bench testing without the original machine, but the test must reproduce the important electrical and control conditions. A suitable fixture should provide the correct I/O interface, supply voltage, command signals, output loads, measurement points, and protection required by the FANUC system. The report should identify the fixture and explain which parts of system compatibility were not tested.
Bench testing can verify relay operation, continuity, contact resistance, switching behavior, and response characteristics. It cannot by itself confirm every controller parameter, rack communication issue, cable fault, grounding problem, or machine-specific interlock. I therefore separate module functional evidence from complete machine compatibility evidence.
If the supplier cannot test the module in the intended FANUC rack, I request a clear limitation statement. The supplier should still provide complete electrical results and confirm that the module was tested with the correct output configuration. This is more useful than a vague claim that the part is compatible with all FANUC systems.
I use a simple five-level evidence scale when comparing suppliers:
| Score | Evidence Level | Buying Interpretation |
|---|---|---|
| 0 | “Untested as pictured” | Highest risk; buy only for repair or parts |
| 1 | Visual inspection only | Identity may be known, function remains unproven |
| 2 | Powers on or one output tested | Basic screening, not a 16-channel acceptance test |
| 3 | Continuity and multiple output checks | Moderate evidence, load and relay details may be incomplete |
| 4 | All 16 channels tested under stated loads | Suitable for technical review if results are documented |
| 5 | Full channel results, relay measurements, compatibility review, burn-in, and warranty | Strongest evidence package for maintenance purchasing |
I would reject a listing that claims “tested good” but provides no serial-number photo, no channel table, and no test conditions. I would also reject a unit with missing covers, damaged terminals, undocumented board repairs, incorrect output configuration, or a part-number mismatch.
A score of 5 still does not remove application responsibility. The buyer must verify voltage, current, load type, common wiring, and controller compatibility. The scoring system only measures how clearly the supplier has demonstrated the condition of the specific unit.
A used AOR16G module should include written warranty or return terms when it is intended for production maintenance. I request the warranty duration, start date, covered failures, exclusions, return authorization process, testing responsibility, and whether compatibility disputes are excluded. A warranty without a defined return process provides limited practical protection.
The acceptance criteria should be written on the purchase order. I would specify the exact part number, serial number, 16-channel test requirement, applicable voltage and current limits, required photographs, report format, and return condition. If the module fails during incoming inspection, the supplier should identify whether the remedy is replacement, repair, refund, or credit.
I also keep the evidence package with the maintenance record. The photographs, test report, invoice, serial number, and receiving inspection results provide traceability if the machine develops a fault later. This is especially important when a used module is installed during an urgent CNC repair.
What Test Evidence Should You Request for a Used AOR16G Module? Request identity verification, complete compatibility information, all-16-channel relay output results, continuity and contact-resistance measurements, load conditions, visual inspection photographs, repair history, and warranty terms. For an A03B-0819-C161 AOR16G, confirm the 16-point relay configuration and compare the test conditions with the applicable 30 VDC, 250 VAC, and 2 A resistance-load limits.
I would not approve a purchase based only on “powers on,” “tested good,” or a generic product photograph. I would ask YaoTai technology or any other supplier to identify the actual serial-numbered unit, explain whether it is used, tested, repaired, or refurbished, and provide a report showing how every output channel was checked. The safest next step is to send the supplier a written inspection checklist before ordering and make acceptance conditional on receiving the specified evidence.